Calibrations

Gas monitoring instruments are designed to protect personnel from unseen hazards that may exist in workplace environments, including confined spaces. It is vital to worker safety that these instruments are maintained and calibrated properly.

Instrument inaccuracy due to improper or irregular calibration can lead to serious accidents. Exposure to excessive levels of toxic gas or an oxygen-deficient environment can cause workers serious illness and even death. Combustible gas explosions are often catastrophic, injuring or killing personnel and destroying property.

The only way to guarantee that an instrument will detect gas accurately and reliably is to test it with a known concentration of gas. Exposing the instrument to a known concentration of test gas will show whether the sensors respond accurately and whether the instrument alarms function properly.

Causes of Calibration Drift

Over time, the accuracy of gas detection instruments can diverge from their calibration settings in several ways:

  • Gradual chemical degradation of sensors and drift in electronic components that occur naturally over time.
  • Chronic exposures to, and use in, extreme environmental conditions, such as high/low temperature and humidity, and high levels of airborne particulates.
  • Exposure to high (over-range) concentrations of the target gases and vapors.
  • Chronic or acute exposure of catalytic hot-bead LEL sensors to poisons and inhibitors. These include: volatile silicones, hydride gases, halogenated hydrocarbons, and sulfide gases.
  • Chronic or acute exposure of electrochemical toxic gas sensors to solvent vapors and highly corrosive gases.
  • " Harsh storage and operating conditions, such as when an instrument is dropped onto a hard surface or submerged in liquid. Normal handling/jostling of the equipment can create enough vibration or shock over time to affect electronic components & circuitry.

Often, after exposure to the more extreme conditions above, when calibration is attempted, the detector will either display a failure message or it will not allow the user to fully adjust the display reading. At this point, the severely damaged sensor must be replaced and/or the detector serviced by qualified personnel.

HOT NEWS

June 1, 2010
Guardian Safety partners with 360Training.com (Read More)
November 12, 2009
Brandon Baldwin completes RKI Instruments' Service & Repair School (Read More)

May 01, 2009
Christopher Settlemire is promoted to Field Supervisor (Read More)

August 08, 2008
Chad Gillies completes Rope Rescue Technician I/II 40-Hour Program
(Read More)

May 02, 2008

Christopher Settlemire & Chad Gillies complete 40-Hour Confined Space Rescue Program (Read More)

READ ARCHIVES
.............................
..........

TECH BULLETINS


January 2010
Weather Damages Void H2S Fixed Gas Detection System Warranty (Read More)
Guardian Safety Services
12625 Jomani Dr., Suite #102 
Bakersfield, CA 93312
Toll Free:  (877) 587-1784
Fax: (661) 587-5749